Download Aging Mgmt Guidelines for Comml Nucl Powerplants [motor ctl PDF

Read or Download Aging Mgmt Guidelines for Comml Nucl Powerplants [motor ctl centers] PDF

Similar nonfiction_6 books

Seminar on Stochastic Analysis, Random Fields and Applications V: Centro Stefano Franscini, Ascona, May 2005

This quantity includes twenty-eight refereed examine or evaluate papers offered on the fifth Seminar on Stochastic techniques, Random Fields and purposes, which happened on the Centro Stefano Franscini (Monte Verità) in Ascona, Switzerland, from might 30 to June three, 2005. The seminar targeted frequently on stochastic partial differential equations, random dynamical structures, infinite-dimensional research, approximation difficulties, and monetary engineering.

Additional info for Aging Mgmt Guidelines for Comml Nucl Powerplants [motor ctl centers]

Example text

In the magnetic starter+ current flowing in the coil of the electromagnet induces a magnetic field that interacts with another ferro-rnagnetic material serving as an ;lrmature, or rnovirlg componerlt. The armature is mechanically connected to a set of contacts such that when the armature is attracted to the magnet the contacts close to start the motor load. " The manual starter, in contrast, uses some external manual force (such as that t'rorn a pushbutton) to close the contacts. , electromagnet or pushbutton).

IEM L3 50 HP Motor .... OL Figure 3-12. Relay Llsed in Voltage Interface. Figure 3-12 represents a voltage change for interfacing two different control voltages. A condition may exist in which the voltage rating of the temperature switch is too low to permit its direct use in a starter control circuit operating at some higher voltage. In this application, the coil of the interposing relay and the pilot device are wired to a low-voltage source of power compatible with the rating of the pilot device.

The line voltage of the power supplied to the motor determines the required primary rating of the control power transformer. The secondary of the transformer must be rated to provide the desired control-circuit voltage and to match the voltage of the contactor operating coil. In addition, the continuous secondary current rating of the transformer must be sufficient to sustain both the magnetizing current of the operating coil and the inrush current generated during initial coil energization. Standard control power transtormers have a 120-volt secondary, which provides a good balance between reliability and safety.

Download PDF sample

Rated 4.16 of 5 – based on 48 votes